The usefulness of an optical monitor for the assessment of human exposure to fine dust in indoor air

Background An important issue in the assessment of health risks related to air pollution with fine dust is the measurement of individual exposure. Such possibilities are provided by relatively easy to use optical monitors. The aim of the presented work was to assess the possibility of using the AM52... Ausführliche Beschreibung

1. Person: Małgorzata Kowalska verfasserin
Weitere Personen: Anna Mainka verfasserin; Walter Mucha verfasserin
Quelle: In Medycyna Pracy (01.04.2019)
Weitere Artikel
Format: Online-Artikel
Sprache: English
Greek, Modern (1453- )
Veröffentlicht: 2019
Beschreibung: Online-Ressource
Online Zugang: Online
Online
Online
Online
Online
Volltext
Tags: Hinzufügen
Keine Tags. Fügen Sie den ersten Tag hinzu!
  Creative Commons License Source: Directory of Open Access Journals (DOAJ).
LEADER 02673nma a2200313 c 4500
001 DOAJ041151593
003 DE-601
005 20190503073215.0
007 cr uuu---uuuuu
008 190503s2019 000 0 eng d
024 7 |a 10.13075/mp.5893.00780  |2 doi 
035 |a (DE-599)DOAJ1fc922eca64642608b5099401361fbe1 
040 |b ger  |c GBVCP 
041 0 |a eng  |a gre 
100 0 |a Małgorzata Kowalska  |e verfasserin  |4 aut 
245 1 4 |a The usefulness of an optical monitor for the assessment of human exposure to fine dust in indoor air  |h Elektronische Ressource 
300 |a Online-Ressource 
520 |a Background An important issue in the assessment of health risks related to air pollution with fine dust is the measurement of individual exposure. Such possibilities are provided by relatively easy to use optical monitors. The aim of the presented work was to assess the possibility of using the AM520 optical monitor to measure individual human exposure to PM 2.5 and PM 10 indoors by determining the calibration factor and assessing the compliance of the measurement with the reference method. Material and Methods As part of the research, indoor concentrations of PM 2.5 and PM 10 and were measured (3 locations in the Gliwice Poviat, March−May 2017) with the use of the SidePak Personal Aerosol Monitor AM520, as well as the reference LVS3D device by means of the gravimetric method. The value of the calibration coefficient for the optical monitor was determined, and the consistency of measurements performed with both methods was assessed. Results The photometric calibration factor ranged 0.33−0.40 and was concurrent with the 0.38 value recommended by the manufacturer. The determination coefficient for the correlation between the measurement results obtained with the optical and gravimetric methods was very high (R 2 = 0.91). Conclusions The presented results are promising and allow for the conclusion that the AM520 optical monitor can be used to assess individual exposure to PM 2.5 and PM 10 indoors. Med Pr. 2019;70(2):213–20 
700 0 |a Anna Mainka  |e verfasserin  |4 aut 
700 0 |a Walter Mucha  |e verfasserin  |4 aut 
773 0 8 |i In  |t Medycyna Pracy  |g  (01.04.2019)  |w (DE-601)DOAJ000027634  |x 0465-5893 
856 4 0 |u http://dx.doi.org/10.13075/mp.5893.00780 
856 4 0 |y DOAJ  |u https://doaj.org/article/1fc922eca64642608b5099401361fbe1 
856 4 0 |u http://www.journalssystem.com/medpr/Przydatnosc-optycznego-miernika-dla-oceny-narazenia-ludzi-na-drobny-pyl-zawarty-w,99266,0,2.html 
856 4 0 |u https://doaj.org/toc/0465-5893 
856 4 0 |u https://doaj.org/toc/2353-1339 
912 |a GBV_DOAJ 
951 |a AR 
952 |j 2019  |b 01  |c 04 

Ähnliche Einträge

Keine ähnlichen Titel gefunden

Privacy Notice Ask a Librarian New Acquisitions