Definition of optimal PEEP by dynamic compliance after lung recruitment maneuver in canine ARDS model

Objective  To investigate the correlation between the optimal lung oxygenation and dynamic lung compliance (Cdyn) during positive end-expiratory pressure (PEEP) titration after lung recruitment maneuver, and explore the method for determining the optimal PEEP titration by Cdyn. Methods  ARDS mod... Ausführliche Beschreibung

1. Person: Liang PAN verfasserin
Weitere Personen: Qing SONG verfasserin; Fei-hu ZHOU verfasserin; Hui LIU verfasserin; Hong-jun KANG verfasserin
Quelle: In Medical Journal of Chinese People's Liberation Army (01.05.2012)
Weitere Artikel
Format: Online-Artikel
Sprache: Chinese
Veröffentlicht: 2012
Beschreibung: Online-Ressource
Online Zugang: Online
Online
Online
Volltext
Tags: Hinzufügen
Keine Tags. Fügen Sie den ersten Tag hinzu!
  Creative Commons License Source: Directory of Open Access Journals (DOAJ).
LEADER 02696nma a2200301 c 4500
001 DOAJ015121437
003 DE-601
005 20190330070406.0
007 cr uuu---uuuuu
008 171226s2012 000 0 chi d
035 |a (DE-599)DOAJ93fed3d3043d46de9ede9b69640a8f76 
040 |b ger  |c GBVCP 
041 0 |a chi 
100 0 |a Liang PAN  |e verfasserin  |4 aut 
245 1 0 |a Definition of optimal PEEP by dynamic compliance after lung recruitment maneuver in canine ARDS model  |h Elektronische Ressource 
300 |a Online-Ressource 
520 |a Objective  To investigate the correlation between the optimal lung oxygenation and dynamic lung compliance (Cdyn) during positive end-expiratory pressure (PEEP) titration after lung recruitment maneuver, and explore the method for determining the optimal PEEP titration by Cdyn. Methods  ARDS model was reproduced by intravenous injection of oleic acid into anesthetized dogs. Lung recruitment maneuver was performed by pressure-controlled ventilation (PCV). The PEEP titration was started from 24cmH2O (T24), and it was decreased by 2cmH2O every 10 minutes. After reaching 6cmH2O (T6) for 10 minutes, the PEEP was immediately adjusted to 0cmH2O (T0). Airway peak pressure (Ppeak), Cdyn and end-inspiratory pressure (EIP) were continually measured by Servo-i monitor, and the variation trends were observed with Open Lung Tool software. At the end of each stage, arterial blood was drawn for blood gas analysis, and static lung compliance was measured using inspiratory and expiratory pause manner. The PEEP at the time of beginning of lung collapse was defined as > 10% decrease of oxygenation index. Results  In all the 6 dogs, when PEEP= 16cmH2O, the oxygenation index decreased by more than 10%. Simultaneously, the lung compliance reached its peak value. This suggested that PEEP at this moment indicated the beginning of lung collapse. Therefore, the optimal PEEP should be 16cmH2O plus 2cmH2O, namely 18cmH2O. Conclusion  During the titration of PEEP after lung recruitment maneuver, the beginning of lung collapse could be inferred from the Cdyn, thereby determining the optimal PEEP. 
700 0 |a Qing SONG  |e verfasserin  |4 aut 
700 0 |a Fei-hu ZHOU  |e verfasserin  |4 aut 
700 0 |a Hui LIU  |e verfasserin  |4 aut 
700 0 |a Hong-jun KANG  |e verfasserin  |4 aut 
773 0 8 |i In  |t Medical Journal of Chinese People's Liberation Army  |g  (01.05.2012)  |w (DE-601)DOAJ000071579  |x 0577-7402 
856 4 0 |y DOAJ  |u https://doaj.org/article/93fed3d3043d46de9ede9b69640a8f76 